LiYY  
LiY-CY  
LiYY-Twisted Pair  
LiYCY-Twisted Pair  
Li2YCY-PiMF  
YSLYCY-JZ  
YSLYCY-JB  
LiYCY-OZ  
LiYCY-JZ  
Li2YCY  
YSLYCY-JZ
350 - 500 V
Cable Construction : - Bare copper, fine wire conductors, bunch stranded to IEC 60228 cl 5
    - Core insulation of special PVC Z 7225
    - Black cores with continous white numbering to DIN VDE 0293
    - Green-yellow earth core in the outer layer (3 cores and above)
    - Cores stranded in layers with optimal lay-length
    - Special PVC Inner sheath
    - Tinned copper, braided screen, approx. 85 % coverage
    - Transparent special PVC outer sheath
    - Extensively oil resistant
    - Flame retardant according to IEC 60332-1
    - PVC outer sheath self-extinguishing and flame retardant according to IEC 60332-1
Note : G = with green-yellow earth core
    X = without green-yellow earth core
Technical Data : Special PVC control cables to DIN VDE 0245.0281 part 13
Conductor resistance : to DIN VDE 0295
Temperature range : Flexing : -5ºC to + 80ºC
    Fixed Installation : -40ºC to -80ºC
Nominal voltage : Uo/U 300/500 V
Test Voltage : 4000 V
Breakdown voltage : Min. 8000 V
Insulation resistance : Min. 20 MOhm x km
Mutual Capacitance : according to different cross-sections 0,5 mm2 to 2,5 mm2
    core/core approx 150 nF/km
    core/screen approx 270 nF/km
Coupling resistance : max 250 Ohm/km
Minimum bending : Flexing : 10 x cable
    Fixed installation : 5 x cable
Radiation resistance : up to 80 x 1.000.000 cJ/kg (up to 80 Mrad)
Application : For use as measuring, control and connection cable for machine tools, conveyor belts,
    tools machineries, plant installations, control and computer units in dry, damp or wet
    rooms at normal stress. The braided copper screen server as electromagnetic screen
    between the internal electric circuits and the surroundings. The transparent outer
    sheath gives the cable an optical revalution.