LiYY  
LiY-CY  
LiYY-Twisted Pair  
LiYCY-Twisted Pair  
Li2YCY-PiMF  
YSLYCY-JZ  
YSLYCY-JB  
LiYCY-OZ  
LiYCY-JZ  
Li2YCY  
LiYY-Twisted Pair
250 V
Cable Construction : - Bare copper, fine wire conductors, bunch stranded to IEC 60228 cl 5
    - Special PVC core insulation Y12
    - Core wrapping with foil
    - Colour coded to DIN 47100
    - Special PVC outer sheath
    - Colour grey
    - Extensively oil resistant
    - PVC self-extinguishing and flame retardant according to IEC 60332-1
Technical Data    
Temperature range : Flexing : -5ºC to + 80ºC
    Fixed installation : -40ºC to + 80ºC
Nominal voltage : - 250 V (not for purposes of high current and power installation)
Test Voltage : 1200 V
Breakdown Voltage : min. 2400 V
Capacitance : core/core approx. 120 nF/km
    core/screen approx. 150 nF/km
Load : 0,14 mm2 = 1,5 A : 0,25 mm2 = 2,5 A
Inductance : approx 0,65 mH/km
Insulation resistance : min. 20 MOhm x km
Minimum bending radius : Flexing : 7,5 x cable
    Fixed installation : 4 x cable
Radiation resistance : up to 80 x 1.000.000 cJ/kg (up to 80 Mrad)
Application : For flexible use with free movements without tensile stress or forced movements in dry,
    moist and wet zones, but not suitable in the open, wherever the construction requires a
    minimum outer diameter. Especially for such areas as tool making and machine industries
    electronic, computer, measurement and control sectors.