| Technical Data |
|
|
| Temperature range |
: |
Flexing : -5ºC to + 80ºC |
| |
|
Fixed Installation : -30ºC to -80ºC |
| Nominal voltage |
: |
Uo/U 300/500 V |
| Test Voltage |
: |
core/core 4000 V |
| |
|
core/screen 2000 V |
| Breakdown voltage |
: |
Min. 8000 V |
| Insulation resistance |
: |
Min. 20 MOhm x km |
| Mutual Capacitance |
: |
according to different cross-sections 0,5 mm2 to 2,5 mm2 |
| |
|
core/core approx 150 nF/km |
| |
|
core/screen approx 270 nF/km |
| Coupling resistance |
: |
max 250 Ohm/km |
| Minimum bending |
: |
Flexing : 10 x cable |
| |
|
Fixed installation : 5 x cable |
| Radiation resistance |
: |
up to 80 x 1.000.000 cJ/kg (up to 80 Mrad) |
| Cable Construction |
: |
- Bare copper, conductors, stranded to IEC 60228 cl 5 |
| |
|
- Core insulation of special PVC Z 7225 |
| |
|
- Black cores with continous white figure imprint to DIN VDE 0293 |
| |
|
- Green-yellow earth core in the outer layer (3 cores and above) |
| |
|
- Foil separator |
| |
|
- Tinned copper, braided screen, approx. 85 % coverage |
| |
|
- Special PVC Inner sheath |
| |
|
- Colour grey |
| |
|
- Extensively oil resistant |
| |
|
- PVC self-extinguishing and flame retardant according to IEC 60332-1 |
| Note |
: |
G = with green-yellow earth core |
| Application |
: |
This cable is an extremely robust control cable which is noted by its high abrasion and |
| |
|
notch resistance properties. They are usually used in applications such as tooling, |
| |
|
machinery and plant construction. Due to the cable resistance to minerals oils and to |
| |
|
coolant emulsions in particular, they are always applicable in rolling mills and steel works. |
| |
|
It is recommended for outdoor installation. Largerly resistance to microbial attack. |
| |
|
The high screening density of the cable assures an interference-free transmission |
| |
|
of pulses and signals. |