| Cable Construction |
: |
- Bare copper stranded wire, 7-wires, adapted to DIN VDE 0881, Suitable for Termi-Point |
| |
|
and solder-free connection technique |
| |
|
- Conductor make-up |
| |
|
0,22 mm2 = 7 x 0,20 mm |
| |
|
0,34 mm2 = 7 x 0,25 mm |
| |
|
0,5 mm2 = 7 x 0,30 mm |
| |
|
- Core insulation of PE, compound type 2YL1 |
| |
|
- Core colours to DIN 47100 with colour repetition |
| |
|
- Core wrapping with foil |
| |
|
- Tinned copper braided screening, coverage approx. 85 % |
| |
|
- Special PVC outer sheath YM2 grey to DIN VDE 0207 part 5 |
| |
|
- Version Yv with reinforced outer sheath of special PVC YM2 black for underground |
| |
|
laying |
| |
|
- PVC outer sheath self-extinguishing and flame retardant according to IEC 60332-1 |
| Technical Data |
|
|
| Temperature range |
: |
Flexing -5ºC to + 70ºC |
| |
|
Fixed installation -30ºC to + 80ºC |
| Conductor resistance |
: |
(loop) at 20ºC |
| |
|
0,22 mm2 max. 186 Ohm/km |
| |
|
0,34 mm2 max. 115 Ohm/km |
| |
|
0,5 mm2 max. 78,5 Ohm/km |
| Operating voltage |
: |
(peak voltage) |
| |
|
Max. 250 V (not for purposes of high current and power installation) |
| Test Voltage |
: |
Core/core 2000 V |
| |
|
Core/screen 1000 V |
| Insulation resistance |
: |
Min. 5 GOhm x km |
| Mutual Capacitance |
: |
at 800 Hz |
| |
|
> 4 pairs max. 60 nF/km |
| |
|
< 4 pairs values extended by 20% |
| Impedence |
: |
100 Ohm + 15 |
| Minimum bending radius |
: |
Flexing : 12 x cable |
| |
|
Fixed installation : 7,5 x cable |
| Application |
: |
The PE-insulated data cable is designed for computer application and data transmission. |
| |
|
It is specially designed for wiring data systems with transmission rates up to 10MB/s, eg. |
| |
|
for interfaces of types RS 422, RS 485. The twisted pair lay-up prevents electrical |
| |
|
unbalances within the cable and this effectively suppresses cross-talk effect. |
| |
|
These cables are designed for limited flexible use as well as for fixed installation in dry |
| |
|
and damp interiors. Yv version reinforced with a black outer sheath suitable for outdoor |
| |
|
and indoor use as well as for direct burial. |