M2X  
M2XY-FR  
M2XCY-FR  
FM2XCY-FR  
M2XH  
M2XCH & M2XCH (EMC)  
FM2XCH  
M2XH-FFR  
M2XCH-FFR  
FM2XCH-FFR  
MGH  
MGCH & MGCH (EMC)  
FMGCH  
MGH-FFR  
MGCH-FFR  
FMGCH-FFR  
MGG  
MGCG  
FMGCG  
MYY  
MYCY  
FLAT MARIN MYY  
LMKK  
LFMKKK  
XLFMKK  
SHORE POWER CABLE  

 

 

MGCH & MGCH (EMC)
0,6 / 1 kV
Cable Structure    
Conductor : Stranded annealed copper wire IEC 60228 class 2 / class 5 (on request)
Insulation : EPR compound
Bedding : Halogen free bedding compound
Screen : Electrolytic plain copper braided screen,
    (EMC) = %100 wrapped electrolytic copper tape
Outer Sheath : Halogen - free, flame retardant thermoplastic polyolefin based compound
    (HM4 / SHF 1) - HD 604 Black or grey
Application : These cables are mainly used in permanent installation in ships. As a result of the
    materials used in the production, they are resistant to all the conditions in the
    marine environment such as dry, wet and oil. Since they are screened by copper wire
    with braided they prevent interference by radio and electronic equipment. Halogen
    free cables enhanced characteristic in case of fire are used for application where
    harm to human life and damage to property must be prevented in the event of fire
Construction : DIN 89158 (IEC 60092/353)
Tests and Material : IEC 60092 / 350 - 351 - 359
Flame Retardant : IEC 60332 / 1
    IEC 60332 - 3 Cat A
Halogen, Gas Content : IEC 60754 / 1-2
Measur. Of Smoke Density : IEC 61034 / 1-2 (DIN EN 50268/1-2)
Perm. Working Temp : -20ºC, + 90 ºC
Min. Bending Radius : 8* cable dia. (mm) fixed
Rated Voltage : 0,6/1 kV
Test Voltage : 3,5 kV