| Cable Structure |
|
|
| Conductor |
: |
Stranded annealed copper wire IEC 60228 class 2 / class 5 (on request) |
| Insulation |
: |
XLPE compound |
| Bedding |
: |
Seperating foil or HF compound |
| Outer Sheath |
: |
Halogen - free, flame retardant thermoplastic polyolefin based compound |
| |
|
(HM4 / SHF 1) - HD 604 Black or grey |
| Application |
: |
The cable are mainly used in permanent installation in ships. As a result of the |
| |
|
materials used in the production, they are resistant to all the conditions in the |
| |
|
marine environment such as dry, wet and oily locations. Halogen free cables with |
| |
|
enhanced characteristic in case of fire are used for application where harm to human |
| |
|
life and damage to property must be prevented in the event of fire |
| Production and Test Standards |
|
|
| Construction |
: |
IEC 60092/353 |
| Tests and Material |
: |
IEC 60092 / 350 - 351 - 359 |
| Flame Retardant |
: |
IEC 60332 / 1 |
| |
|
IEC 60332 / 3A |
| Halogen, Gas Content |
: |
IEC 60754 / 1-2 |
| Measur. Of Smoke Density |
: |
IEC 61034 / 1-2 |
| Perm. Working Temp |
: |
-20ºC, + 90 ºC |
| Min. Bending Radius |
: |
6* cable dia. (mm) fixed |
| Rated Voltage |
: |
0,6/1 kV |
| Test Voltage |
: |
3,5 kV |