| Cable Structure |
|
|
| Conductor |
: |
Stranded annealed copper wire IEC 60228 class 2 / class 5 (on request) |
| Insulation |
: |
EPR rubber compound |
| Laid Up |
: |
Cores laid up in pairs, pairs laid up concentrically |
| Separating Foil |
: |
Over cable core, foil |
| Screen |
: |
Electrolytic plain copper braided screen |
| Separating Oil |
: |
Above braided screen, foil |
| Outer Sheath |
: |
Chloroprene based flame retardant and oil resistant outer jacket |
| Application |
: |
The cable are mainly used above and below deck of the ship as control and |
| |
|
communication cables in radio, radar and information systems. |
| Production and Test Standards |
|
|
| Construction |
: |
DIN 89159 (IEC 60092 / 375,376) |
| Tests and Material |
: |
IEC 60092 /350,351,359 |
| Flame Retardant |
: |
IEC 60332 / 1 |
| |
|
IEC 60332 - 3 Cat A |
| Working Temp |
: |
-20ºC, + 90 ºC |
| Min. Bending Radius |
: |
8 cable dia. (mm) |
| Rated Voltage |
: |
60 - 250 V |
| Test Voltage |
: |
1,5 kV |

|
|
|